30/11/2016· PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Cross C/7.5 PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Cap C/7.6 PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for MJ Solid Sleeve C/7.7 PVC AWWA C-900 C/7
PVC C-900 and C-905 pipe shall be cast-iron-pipe-equivalent O.D. type as called for in the Bid, Plans, and Specifiions. All PVC C-900 and C-905 pipe and materials used for potable service shall be NSF 61 certified. Only elastomeric-gasket type joints shall be
C900 PVC pipe is unaffected by electrolytic or galvanic corrosion, or corrosive soils, unlike HDPE and iron pipe systems. CONS C900 PVC pipe is generally not as strong as ductile iron nor does it have competitive working pressures with ductile iron pipe.
Diamond Plastics Corporation is the producer of the world''s largest, corrosion free PVC pipe through seven strategically loed plants throughout the United States, fulfilling your water, sewer and irrigation piping needs since 1982.
This standard covers 4-in. through 12-in. (100 mm through 300 mm) polyvinyl chloride (PVC) pressure pipe and fabried fittings with cast-iron-pipe-equivalent (CI) outside diameter (OD) dimensions and with wall-thickness-dimension ratios (DRs) 14, 18, and 25. The Puhui Pipe manufacturer in China
(flow coefficient, C=150), for savings in pumping costs, and size of the pipe. Nominal Laying length = 20 feet (Laying length tolerances are in accordance with AWWA and CSA standards) AWWA C900-16 305 psi (DR 14) 235 psi (DR 18) 200 psi (DR 21)
AWWA’s PVC pipe and fittings standards define the basic properties of PVC com pound, using the China Society for Testing and Materials (ASTM) Specifiion D1784, Standard Specifiion for Rigid Poly (Vinyl Chloride) (PVC) Compounds and
PVC Gravity Sewer: PVC C900 is required in well field protection areas. PVC SDR 26 heavy walled sewer pipe will be the minimum dimension allowed after Sept 2017. High Density Polyethylene (HDPE) Pipe HDPE pipe shall be used for directional drill and slip-line
3/10/2014· AWWA designation nuer (AWWA C 900), manufacturer’s name and code. Additional certified seals printed on the pipe are: NSF-pw, NSF-61, UL 1285, Factory Mutual (FM roved for DR18 and DR14 series only).
AWWA C-900 with outside diameter equal to that of standard ductile iron pipe. PVC pipe shall be Class 150, or DR 18. I. PVC Pipe Fittings: Shall be of same class and rating of PVC pipe. Fittings for AWWA C-900 PVC pipe shall be ductile iron, mechanical
Works with A/C, PVC C-900, cast iron and ductile iron pipe Temporary slide gate Drill bushing stabilizes the shell machine A ball nosed reamer cleans away any tuberculation and forms a smooth sealing surface for the QuikValve insert. 3. Ream the pipe as a 3
This standard was updated August 1, 2016, and includes our larger diameter water pipe. DURA-BLUE C900 Our C900 line meets the requirements of AWWA C-900, UL 1285, FM 1612, CAN/CSA-B137.3 and BNQ NQ3624-250 Standards, as indied, for potable water transmission mains and for fire protection …
Typical Valve Installation AWWA C-900 P.V.C. Pipe W-0155 4" Blowoff Assely (Above Ground) W-0214 Bell and Spigot Joint Bonding Detail HDPE Cylinder Pipe W-0310 Formed Bell & Spigot Joint HDPE Cylinder CML-CC & CML-AW W-0320 Puhui Pipe manufacturer in China
Restraint Harness for AWWA C900 PVC Pipe Joints The Series 1900 is a split serrated restraint harness for restraining C900 PVC Pipe Joints. It''s comprised of two split serrated restraint rings; one on the plain end or spigot of pipe and the other behind the bell.
Standard Specifiions Material PVC compound meets ASTM D 1784, cell class 12454. Pipe Meets AWWA C900. Class 100 meets requirements of DR 25. Class 150 meets requirements of DR 18. Class 200 meets requirements of DR 14. Elastromeric Seal
strength and corrosion resistance you are now receiving from the C-900 pipe. These HARCO PVC fittings make possible an all PVC system. Fittings meet DR18 requirements of AWWA C-900. SUGGESTED SPECIFIION All fittings for C-900 pipe shall be Puhui Pipe manufacturer in China
Blue Brute pipe shall conform to AWWA C900 “Poly (Vinyl Chloride) (PVC) Pressure Pipe (4" - 12") for Water,” and certified to CSA B137.3 “Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure liions.” Blue Brute DR25 shall have a pressure class of 690
7.2.3.3 Standard dimension fittings for PVC C-900 pipe and ductile iron pipe shall be of ductile iron with either "push-on" or mechanical joints (See Section 3.4.6.5). The fittings shall comply with all requirements of AWWA Standard C-110 (ANSI A21.10) and shall
AWWA Headquarters 6666 W. Quincy Ave. Denver, CO 80235 USA Phone: 303.794.7711 or 800.926.7337 Fax: 303.347.0804 AWWA Government Affairs Office 1300 Eye St. NW Suite 701 Washington, DC 20005-3314 USA Phone: 202.628.8303
The pipe conforms to AWWA C900 pressure class 165 psi (DR 25), 235 psi (DR 18), 305 psi (DR 14), 200 psi (DR 21), 125 psi (DR 32.5), 100 psi (DR 41), and 80 psi (DR 51). It carries approval of ANSI/NSF Standard 61, UL 1285 and FM 1612 (DR 18 and DR 14
Diamond Plastics manufactures 4” through 12” cast iron O.D. PVC pressure pipe in accordance with AWWA C900, Standard for Polyvinyl Chloride (PVC) Pressure Pipe and Fabried Fittings, 4 In. Through 12 In. (100 mm Through 300 mm) for Water Transmission
Table of Contents WSSC STANDARD DETAILS NOVEER 2016 Page C-3 PVC AWWA C-900 Pipe Anode Protection for Fire Hydrant Lead Pipe C/7.8 PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Water House Connections C/7.9 PVC
31/7/2015· Injection molded PVC fittings are covered in AWWA C907. C900 pipe is delivered in standard laying lengths of 20 feet +/- 1 Inch. C900 pipe is also suitable for use in waste water force main services. C905 is a comparable standard for potable water PVC pressure